C-FLEX TITRATION POLYSOMNOGRAM

INDICATIONS


Mr. Michael J. Ederer is a 40-year-old gentleman referred for pulmonary and sleep disorders evaluation.  Please see Mr. Ederer's history and physical dictation for details of his presentation.  Mr. Ederer's diagnostic polysomnogram revealed a moderate severity obstructive sleep apnea syndrome.  That study also revealed supine worsening of sleep-disordered breathing and intermittent hemoglobin desaturation associated with sleep-disordered breathing.  Mr. Ederer returns for a 2nd polysomnogram with the addition and titration of C-flex therapy for treatment of his obstructive sleep apnea syndrome and related problems.

DIAGNOSIS

Obstructive sleep apnea syndrome, moderate severity (327.23).

RESULTS

There were 7.9 hours of recorded time and 7.4 hours of sleep recorded.  Total sleep efficiency was normal at 94%.  A 358 minutes of sleep time recorded in the supine position and 88 minutes were recorded in the nonsupine sleep position.  Latency to sleep onset was shortened at 6 minutes, suggesting hypersomnia.  Latency to stage REM onset was prolonged at 123 minutes.  There were 17 brief awakenings for 21 minutes of awake time after sleep onset. There was a decrease in the percentages of stage III, IV, and stage REM sleep and an increase in percentage of stage II sleep.  Compared to the diagnostic polysomnogram, there was an increase in percentages of stage III and stage IV sleep.  Hypnogram revealed several awakenings and 4 short periods of stage REM sleep.

The average sleeping heart rate was 64 beats per minute.  Mild variation of heart rate was seen with events of sleep-disordered breathing and arousals. A rare PVC was seen; 41 periodic limb movements were scored, but only 2 of these events were associated with arousal and none were associated with awakening. Total PLM index was 5.5 and the PLM index with arousal was only 0.3.

Mr. Ederer was fitted with a Respironics ComfortGel, size small interface and C-flex therapy was titrated over range of pressures from 4 to 11 cm of water.  Mr. Ederer showed improvement at all C-flex pressures tested and the best results were seen at a C-flex pressure setting of 9 cm of water, 68 minutes of sleep time was recorded at this pressure setting and there were no apneas and no hypopneas scored for respiratory disturbance index of 0.  This is a marked improvement compared to the pretreatment respiratory disturbance index of 22.5.  In addition, he was able to enter a short period of stage REM sleep in the supine position at this pressure setting.  Snoring was controlled and no hemoglobin desaturations occurred at this pressure setting.  Mr. Ederer also did well at C-flex pressure settings of 7, 8, and 10 cm of water.

Mr. Ederer awakened from the study, feeling "better than usual."  He estimated that it took about 3 minutes to fall asleep and he awakened 4 times during the night, sleeping an estimated 8 hours.  His blood pressure study onset was 133/75 and 129/72 at the end of the study.

RECOMMENDATIONS

I will review these results with Mr. Ederer and recommend to begin a trial of C-flex therapy at a pressure setting of 9 cm of water with a Respironics ComfortGel size small interface or the interface of his choice. I will ask him to return in a couple of weeks to see if he was having any initial problems with C-flex therapy. 

STUDY : SPLIT-NIGHT POLYSOMNOGRAM

STUDY : SPLIT-NIGHT POLYSOMNOGRAM 


INDICATIONS


Ms. xxxxx is a 60-year-old lady presenting for re-evaluation of her obstructive sleep apnea syndrome.  Ms. xxxx was diagnosed several years ago with severe obstructive sleep apnea and has been off C-flex therapy for at least a couple of years.  She has had weight gain and worsening of sleep quality.  Please see Ms. xxxxx history and physical dictation for details of her presentation.  Ms. xxxxx underwent split-night polysomnogram testing at Thomas Hospital Sleep Services on May 13, 2009.   

DIAGNOSES


Obstructive sleep apnea syndrome, severe (327.23)


RESULTS  



There were 7.5 hours of recorded time and 6 hours of sleep recorded. The entire sleep time was spent in the nonsupine sleep position.  Total sleep efficiency was reduced at 80%.  Latency to sleep onset was prolonged at 47.5 minutes.  A 10-milligram dose of Ambien was given to help with sleep onset.  Latency to stage REM onset was prolonged at 126.5 minutes.  There were 15 awakenings for 42 minutes of awake time after sleep onset.  Sleep staging revealed an increase in percentages of stage I and stage II sleep with marked reduction in percentage of stage REM sleep and no stage III or stage IV sleep recorded.  The hypnogram revealed frequent awakenings and difficulty maintaining sleep stages with 2 periods of stage REM sleep after the initiation of C-flex therapy.

The average sleeping heart rate was 68 beats per minute.  A few PVCs were seen.  There was variation in heart rate with events of sleep-disordered breathing and arousals.  Moderate snoring was heard and this decreased with titration of C-flex therapy.  There were 5 periodic limb movements scored and 1 event was associated with arousal, no events were associated with awakening.  The total PLM index was 0.8.  The PLM index with arousal was 0.2.

There were 121 minutes of monitored time and 67.5 minutes of sleep time recorded without the benefit of C-flex therapy.  In that time, there were 67 obstructive apneas and 85 obstructive hypopneas scored for a total respiratory disturbance index of 135.1 consistent with a very severe obstructive sleep apnea syndrome.

Ms. xxxxxx was fitted with a ResMed Swift LT small interface and C-flex therapy was titrated over range of pressures from 4 to 9 cm of water.  Best results were seen at C-flex pressure setting of 9 cm of water and 56.5 minutes of sleep time recorded at this pressure setting.  In this time, there were no apneas and only 4 hypopneas for a respiratory disturbance index of 4.2, a remarkable improvement compared to the pretreatment respiratory disturbance index of 135.1.  In addition, Ms. xxxxx was able to enter and maintain stage REM sleep in the nonsupine sleep position at this pressure setting.  There were no significant hemoglobin desaturations and snoring was controlled at this pressure setting.  The lowest hemoglobin saturation recorded in this study was 83% with 97% of sleep time spent at hemoglobin saturations greater than 89%.

Ms. xxxxx awakened from the study feeling "tired."  She estimated it took about 30 minutes to fall asleep and that she awakened 4 times during the night sleep, an estimated 5 hours.  Her blood pressure study onset was 161/88 and 159/86 at the end of the study.
 
RECOMMENDATIONS


I will review these results with Ms. xxxxx and recommend she restart C-flex therapy at a pressure setting of 9 cm of water with a ResMed LT Swift size small interface with interface of her choice.  I will ask her to return in a couple weeks if she is having any initial problems with C-flex therapy.  She will be urged to avoid the supine sleep position.

Why is earth special???

Our planet known as earth is very special and it has a special spot in solar system. There are so many reasons - -Sprawling continents -B...